GMOX-PR-12DN-C16_安士能安全监控器_哪里有现货特价?
欢迎咨询 189-1774-1718 。
安士能安全监控器、GMOX-PR-12DN-C16技术资料简介:
Mechanical values and environment
Housing material
Stainless steel
Weight
Net
0,8 kg
Ambient temperature
0 ... 55 °C
Degree of protection
IP20
permissible shock and vibration load
According to EN 61 131-2
Mounting method
Mounting rail 35mm according to DIN EN 60715TH35
Number of OSSDs
16 (4 fed out)
Number of masters
1
Relay outputs 1.13, 2.13 semiconductor outputs 1.14, 2.14, 3.14, 4.14
Number of outputs
4
EDM1/Start1: 1.Y1; EDM2/Start2: 2.Y1; EDM3/Start3:1.Y2; EDM4/Start4: 2.Y2
Number of inputs
4
Electrical connection ratings
ASi voltage
DC
30 V
ASi operating current
max.300 mA
LED indicator
LED power, power supply ON
LED PROFIBUS master detected
LED config error configuration error
LED U AS-i voltage OK
LED AS-i active AS-i operation normal
LED prg enable automatic slave programming possible
LED prj mode, configuration mode active
LED AUX auxiliary power is present
4 x LEDs EDM / Start state of the inputs for the external device monitoring circuits: LED off: open, LED on: closed
4 x LEDs output circuit state of the output circuits: LED off: open, LED on: closed
Rated insulation voltage Ui
500 V
Power consumption
9 W
Connection cross-section
For wire
2x (0.5...1.5) mm2
Flexible wire for cable end sleeve
2x (0.5...1.5) mm2
2x AWG 24 to 12
Response delay
Safety circuit off
max.40 ms
Switch-on delay
max.10 s
ASi cycle time
150 µs 150 x (number of slaves + 2)
Card slot
Yes
Relay outputs 1.13, 2.13 semiconductor outputs 1.14, 2.14, 3.14, 4.14
Type of output
Output switching elements, output circuits 1, 2, 3 and 4
EDM1/Start1: 1.Y1; EDM2/Start2: 2.Y1; EDM3/Start3:1.Y2; EDM4/Start4: 2.Y2
Type of input
Feedback loop/start
Interface, bus
Data interface
PROFIBUS according to EN 50 170-3
Serial interface RS 232
Data rate
9,6 ... 12000 kbit/s
Peripheral equipment
Decentralized peripheral equipment mapping of the AS-i slaves as I/O process data in the PROFIBUS; complete diagnostics and configuration via PROFIBUS DP master
Controls and indicators
Control/indicator
4 buttons
Display
LCD AS-i slave address indication, error messages
Miscellaneous
in compliance with
EN 61 000-6-2, EN 61 000-6-4, EN 62 061, IEC 61 508, EN ISO 13 849-1
Reliability values acc. to EN ISO 13849-1
Performance Level
PL e
Category
4
PFHD
5.36 x 10-9
SIL CL
3
Mission time 20 y。
GMOX-PR-12DN-C16,安士能安全监控器。