Housing material Plastic, PBT
Weight
Net 0,12 kg
Ambient temperature -20 ... 55 °C
Degree of protection IP67
Resilience to vibration In acc. with EN IEC 60947-5-2
Mounting distance min.40 mm
Installation position Any
Tightening torque
Fixing screws max.1 Nm
Ready delay 10 s
Switching frequency max.1 Hz
Connection M12 plug connector, 8-pin
Electrical connection ratings
Operating voltage DC
UB 24 V DC  15% ... 15% Reverse polarity protected, regulated, residual ripple < 5%, PELV
Current consumption
No load on outputs max.50 mA
Fusing
External (operating voltage) 0,25 ... 8 A
Rated insulation voltage Ui 300 V  
Rated impulse withstand voltage Uimp max.1,5 kV
EMC protection requirements In accordance with EN IEC 60947-5-3 and EN IEC 61326-3-1
Degree of contamination (external, according to EN 60947-1) 3
Switch-on time
Safety outputs max.400 ms
Safety class III
Risk time according to EN 60947-5-3
Delay per device 5 ms
Single device max.260 ms
Monitoring output OUT
Type of output p-switching, short circuit-proof
Switching current max.200 mA
Output voltage 0,8 x UB ... UB V DC  
Safety outputs OA/OB
Test pulses max.1 ms
Type of output Semiconductor outputs, p-switching, short circuit-proof
Switching current
per safety output 1 ... 400 mA
Output voltage
HIGH U(OA) / U(OB) UB-1,5 ... UB V DC  
LOW U(OA) / U(OB) 0 ... 1 V DC
Utilization category according to EN 60947-5-2
DC-13 24V 400mA 
Rated conditional short-circuit current max.100 A
Off-state current Ir max.0,25 mA
Discrepancy time max.10 ms
Operating distance
Repeat accuracy R
According to EN 60947-5-2 ≤ 10
Miscellaneous
For the approval according to UL the following applies Operation only with UL class 2 power supply, or equivalent measures
Reliability values acc. to EN ISO 13849-1
Monitoring of the safety guard position
Category 4
Performance Level PL e
PFHD 2.1 x 10-9
Mission time 20
in combination withActuator CES-A-BBA
Operating distance
Switch-on distance 18 mm
Assured switch-off distance Sar max.45 mm  
Assured operating distance Sao min.15 mm  
Switching hysteresis 1 ... 3 mm  
in combination withActuator CES-A-BPA
Operating distance
Switch-on distance 22 mm  
Assured switch-off distance Sar max.58 mm
Assured operating distance Sao min.18 mm
Switching hysteresis 1 ... 2 mm
in combination withActuator CES-A-BRN-100251
Operating distance
Switch-on distance 27 mm
Assured switch-off distance Sar max.75 mm
Assured operating distance Sao min.20 mm  
Switching hysteresis 3 mm  
in combination withActuator CES-A-BDA-18-156935
Operating distance
Switch-on distance 19 mm  
Assured switch-off distance Sar max.45 mm  
Assured operating distance Sao min.10 mm  
Switching hysteresis 1 ... 3 mm  。